1126
Guide to Feature Programming
Program
Number
Program Name/Description
Input Data
Default
16-01-03
Department Group Basic Data Setup
–
Department Routing When Busy (Auto Step
Call)
Assign whether a call to busy station Hunts (1)
or Not Hunts (0) to the next available member
of the Hunt Group (Department Group).
Refer
to set up the
Department Group.
0 = Normal (Intercom caller to
busy department member hears
busy)
1 = Circular (Intercom callers to
busy department member routes
to idle member)
0
16-02-01
Department Group Assignment for
Extensions
Set up the Department Group called by the pilot
number and the extension priority when a group
is called.
Call Pickup Groups are set up in 23-02.
Department Groups 1 ~ 64
Priority 1 ~ 9999
Default = 1
extensions in
Department
Group 1 with
priority in port
order:
Port 1 priority = 1
Port 256 priority
= 256
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
Extension port
101 = Class 15
All other
extension port =
Class 1
20-09-07
Class of Service Options (Incoming Call
Service)
– Call Queuing
Turn Off or On Call Queuing to the extension.
Set to Off for Station Hunting to work.
Program 20-13-06 must be set to 0 (Off) for
this feature to work.
0 = Off
1 = On
COS 1 ~ 15 = 1
20-13-06
Class of Service Options (Supplementary
Service)
– Automatic Off-Hook Signaling
(Automatic Override)
Allow a busy extension to Manually or
Automatically receive off-hook signals. Set to 0
for Station Hunting to work.
This setting is to receive incoming call
signaling information during call queuing.
0 = Manually
1 = Automatically
COS 1 ~ 15 = 1
Operation
To make a Step Call:
1.
Place a call to a busy extension.
Summary of Contents for Univerge SV9100
Page 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Page 64: ...64 Required Component s None ...
Page 238: ...238 Walking Code Restriction 663 ...
Page 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Page 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Page 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Page 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Page 407: ...407 ICM Distinctive Ringing Flow Chart ...
Page 442: ...442 CCIS Standard Calls ...
Page 447: ...447 CCIS VE Standard Calls ...
Page 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Page 461: ...461 CCIS VE 911 Calls ...
Page 637: ...637 Cascade Message Notification Flow Chart 1 ...
Page 638: ...638 Cascade Message Notification Flow Chart 2 ...
Page 639: ...639 Cascade Message Notification Flow Chart 3 ...
Page 655: ...655 Cascade Message Flow Chart 1 ...
Page 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Page 813: ...813 ...
Page 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Page 915: ...915 Communications Interface feature for more ...
Page 916: ...916 ...
Page 917: ...917 Operation None ...
Page 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Page 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Page 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Page 1030: ...1030 Multiline Room Monitoring ...
Page 1031: ...1031 Single Line Telephone Room Monitoring ...
Page 1146: ...1146 SMDR Flowchart Continued ...
Page 1147: ...1147 SMDR Flowchart Continued ...
Page 1371: ...1371 ...
Page 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Page 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...