User’s Guide Zephyr TS
Troubleshooting
AP-75390 - Revision 1.0
261
8
How to analyse the pattern
Step 1:
Take a polyknit wiper and softly wipe over the first swath (which is not cured) in
diagonal direction.
Step 2:
Check where the boundary of the “cured” - “non-cured” zone is.
Step 3:
In the middle of the two swaths, a line is printed. This line must fall together with the
boundary of the “cured” - “non-cured” zone.
Now there are 3 possible results:
The cured - non-cured zone is lying on top of the border line.
No UV lamp adjustment necessary.
The cured - non-cured zone is lying above the border line.
The left or right UV lamp needs to be adjusted. Contact your Mutoh Service technician.
The cured - non-cured zone is lying below the border line.
The left or right UV lamp needs to be adjusted. Contact your Mutoh Service technician.
N°
Description
1
UV resistant glove
2
Polyknit wiper
3
Wiping direction
4
Boundary of cured - non-cured zone
5
Border line between swaths