CHAPTER 3.0 Wiring and Installation
3-56
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
3.13.2 A & B Size Power Stage
-
Fixed connector: 12 pins, male connector
-
Mating connector, 12 pins, female, supplied with the drive. Phoenix Contact (Part # 1767106)
-
A size wiring: cable 14AWG (2.1 mm
2
). Wire stripping: 7 mm
-
B size wiring: cable 12AWG (3.3 mm
2
). Wire stripping: 7 mm
-
Tightening torque: 0.5Nm.
Pos. Name Function
J6.1
-AT
DC Bus (-)
J6.2
+AT
DC Bus (+)
J6.3 RR
Regeneration
Resistance
J6.4
U1
Phase “L1”, three-phase voltage input 230/460Vac
±
10%
J6.5 V1
Phase “L2”, “, three-phase voltage input 230/460Vac
±
10%
J6.6 W1
Phase “L3”, “, three-phase voltage input 230/460Vac
±
10%
J6.7
PE
Motor Protective Earth
J6.8 W2
Motor
Phase
W
J6.9 V2
Motor
Phase
V
J6.10 U2
Motor
Phase
U
J6.11
24V
+24V Logic Backup Supply
J6.12
0V
Logic Supply Return
-
Fixed connector: 2 pins, male connector
-
Mating connector, 2 pins, female, supplied with the drive. Wago (Part # 231-102/026-000)
-
C & D size wiring: cable 14 AWG (2.1 mm
2
).
-
Stripping Length 8mm
Pos. Name Function
J8.1
24V
+24V Logic Backup Supply
J8.2
0V
Logic Supply Return
-
PE Stud wiring: cable 6 AWG (13mm
2
)
Pos. Name Function
PE
PE
Protective Earth Stud on Chassis