APPENDIX B – GUI
B-34
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
B.2.16.33 Resolver
Parameters
The Resolver Parameters panel allows the user to set the parameters of this motor position feedback sensor.
•
Resolver Poles
→
The number of resolver poles.
•
Resolver Transformer Turns Ratio
→
A physical characteristic of the resolver, which determines the amplitude
of the resolver reference.
•
Resolver reference amplitude
→
This is the voltage output from the DS2110 to drive the resolver.
•
Resolver position
→
The multi-turn position derived from the resolver input position and used as feedback in
the position loop if resolver position is selected for the position loop feedback
•
Resolver commutation position
→
The electrical angle of the resolver. Depending on the pole count of the
resolver this value is proportional to the mechanical angle.