B.2.16.75 Fault
History
This panel allows the user to examine the internal event log of the drive.
Bytes Used Since Controller Reset - this is the number of bytes used since last reset.
Event Log Current Position – the next byte position that will be written in the event log.
Event Log Read Position – the first byte position that will be read from the event log when the refresh button is
selected. This number will be automatically re-adjusted to the start of a record. After a refresh has completed, this
number will be set to the end of the block of bytes that have been read
No of records to display – this is the number of event log records that will be read when the refresh button is
selected. Each event log record has a length of 12 bytes.
In the event log display the columns are defined as follows:
Time – this is the time recorded from the drive total elapsed time indicator when the event occurred. The time is in
seconds and is the total amount of time for which the drive has been powered up until the event occurred.
Temperature – the temperature at which the event occurred
Status – a description of the event logged
Action – whether the event was set or cleared