CHAPTER 4.0 Getting Started
4-10
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
4.10 Status & Faults
Before high power can be applied all faults must be cleared from the DS2110. The prefix “U” indicates a warning
and an “F” indicates an error on the DS2110’s 7-segment display.
Refer to Section 5.11 Drive Monitoring and
Fault Detection.
After the motor and regeneration parameters have been entered as detailed in the previous sections, all faults
should be cleared as follows:
“
Status and Faults
→
Clear Faults
→
Clear Faults
”.
The DS2110 should now display a “U1” to indicate “High Power Not Ready”. All other errors and warnings should
be removed. Should an error indication remain, power-cycle the drive.
Should a persistent error occur
Refer to DS2110 User’s Manual Section 5.11 Drive Monitoring and Fault
Detection
to identify the error. Where applicable, check all connections and parameter settings associated with
the particular error.
Figure 4.9 Clearing Faults
Failure to remove All errors before high power is applied will result in the soft start relay remaining
open and no DC Bus voltage being applied to the system