APPENDIX F – DEVICENET
TM
MEZZANINE CARD
F-9
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
MOVE_TYPE_1 65201
u16
0
0
2
0x74
0x02
Select Move Type: 0=Absolute,
1=Relative, 2=Compound
MOVE_TARGET_1 65202
f32
0
-
FLT_MAX
FLT_MAX
0x74
0x03
Select Move Target Position for
Move 1
MOVE_SPEED_1 65203
f32
0
-
FLT_MAX
FLT_MAX
0x74
0x04 Select Move Speed for Move 1
MOVE_ACC_1 65204
f32
0
0
FLT_MAX
0x74
0x05
Select Move Acceleration for
Move 1
MOVE_DEC_1 65205
f32
0
0
FLT_MAX
0x74
0x06
Select Move Deceleration for
Move 1
ANALOG_INPUT_SELECTOR 65206
u16 1
0
1
0x74
0x07
Select analog input (0=Analog
Input 1, 1=Analog Input 2)
COMMAND_DIRECTION 65207
u16
0 0 1
0x74
0x08
Select Analog Command
Direction (0=RetractToExtend for
Increasing V or mA,
1=ExtendToRetract for
Increasing V or mA)
NEUTRAL_
POSITION_SELECTOR 65208
u16
0
0 6
0x74
0x09
Select Neutral Position on mA
Command Loss (0=Act.Pos,
1=Move 2, 2=Move3 ... 6=Move7
Position)
ANALOG_
COMMAND_DEADBAND
65209 f32
0
0 FLT_MAX 0x74
0x0A
Set analog command deadband -
Drive will ignore command
change smaller than this setpoint
MOVE_TYPE_2 65211
u16
0
0
2
0x74
0x0C
Select Move Type: 0=Absolute,
1=Relative, 2=Compound
MOVE_TARGET_2 65212
f32
0
-
FLT_MAX
FLT_MAX
0x74
0x0D
Select Move Target Position for
Move 2
MOVE_SPEED_2 65213
f32
0
-
FLT_MAX
FLT_MAX
0x74
0x0E Select Move Speed for Move 2
MOVE_ACC_2 65214
f32
0
0
FLT_MAX
0x74
0x0F
Select Move Acceleration for
Move 2
MOVE_DEC_2 65215
f32
0
0
FLT_MAX
0x74
0x10
Select Move Deceleration for
Move 2
MOVE_TYPE_3 65221
u16
0
0
2
0x74
0x16
Select Move Type: 0=Absolute,
1=Relative, 2=Compound
MOVE_TARGET_3 65222
f32
0
-
FLT_MAX
FLT_MAX
0x74
0x17
Select Move Target Position for
Move 3
MOVE_SPEED_3 65223
f32
0
-
FLT_MAX
FLT_MAX
0x74
0x18 Select Move Speed for Move 3
MOVE_ACC_3 65224
f32
0
0
FLT_MAX
0x74
0x19
Select Move Acceleration for
Move 3
MOVE_DEC_3
65225
f32
0
0
FLT_MAX
0x74
0x1A Select Move Deceleration for