CHAPTER 2.0 Safety & EMC Instructions
2-4
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
As no fuses are provided inside the drive, the DS2110 must be provided with suitable fusing to protect the drive.
The fuses required for each DS2110 model are detailed in the following table It is recommended to use UL
certified fuses and fuse blocks
DS2110 Models
Size
μ
A
Notes
Size 3/9
6/22
Short Circuit Rating
5,000 Amps
rms
Power Line Fuse
25A, 660V FWP25-A1F
Semiconductor (Cooper Bussmann)
Recovery Resistor Fuse
Contact Moog Application Engineering for Advice
24Vdc Aux. Pwr. Fuse
3A, 250V
Delayed
DS2110 Models
Size A
Size B
Notes
Size 8/22
10/42
14/42
Short Circuit Rating
5,000 Amps
rms
Power Line Fuse
50-FE 690V
Semiconductor (Cooper Bussmann)
Recovery Resistor Fuse
Contact Moog Application Engineering for Advice
24Vdc Aux. Pwr. Fuse
3A, 250V
Delayed
DS2110 Models
Size C
Size D
Notes
Size 20/45
25/70
30/90
50/140
60/180
Short Circuit Rating
5,000 Amps
rms
10,000
Amps
rms
Power Line Fuse
100-FE 690V
160-FEE 690V
Semiconductor (Cooper Bussmann)
Recovery Resistor Fuse
Contact Moog Application Engineering for Advice
24Vdc Aux. Pwr. Fuse
3A, 250V
Delayed
DS2110 Models
Size E
Notes
Size 100/240
Short Circuit Rating
10,000 Amps
rms
Power Line Fuse
315-FM
Semiconductor (Cooper Bussmann)
Recovery Resistor Fuse
Contact Moog Application Engineering for Advice
24Vdc Aux. Pwr. Fuse
3A, 250V
Delayed
Table 1 - Recommended DS2110 Fusing
All external d.c. supply voltages used with the DS2110 Series Controllers must be derived from a Safety Extra
Low Voltage (SELV) supply as defined by standard EN60950. Such SELV voltages do not exceed a value of 60
Vd.c. or 42.4 Va.c. peak under normal conditions and are supplied by circuits which are separated from all
hazardous voltage conductors by permitted safety methods such as reinforced insulation.
All external electrical wiring connected to this equipment must be colour coded in accordance with European
Standard EN 60204-1 requirements.
All wires and cables entering and leaving the IP54 rated enclosures or cabinets containing the DS2110 Controllers
and Regen resistor(s) must be protected and anchored in accordance with the requirements of EN 60204-1.
Required for
CE-Compliance