APPENDIX B – GUI
B-45
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
B.2.16.48 Memory Status Byte 2
MEMORY STATUS BYTE 2 :
•
Power Save NVM Checksum
→
Indicates that the checksum for the data in the drive internal power save
NVM is incorrect. This is for information only, it does not cause a fault condition on the drive.
•
Error log NVM Checksum
→
Indicates that the checksum for the data in the drive internal error log NVM is
incorrect. This is for information only, it does not cause a fault condition on the drive.
B.2.16.49 Power Status Byte 1
POWER STATUS BYTE 1 :
•
Bus Over-Voltage
→
Indicates that the bus over-voltage limit is exceeded.
•
Bus Under-Voltage
→
Indicates that the bus under-voltage limit is exceeded.
•
Regen Initialisation
→
Indicates a fault during regeneration initialisation.
•
Regen Short-Circuit
→
Indicates that there is a regeneration short circuit fault.
•
Bus Voltage
→
Indicates whether bus voltage is active.
•
Dynamic Brake
→
Indicates that there is a dynamic brake fault.