APPENDIX E – ANALOG I/O MEZZANINE CARD
E-1
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
E.1 Introduction
An Analog Input and Output option of the DS2110 Control Stage is available. This section will cover the
connector details and basic functionality.
E.2 Overview
The Analog I/O option has two analog inputs and outputs available for motion control signals and feedback. The
Analog I/O port allows for 2 configurable analog input channels and 2 analog output channels for external control
system integration. The simulated encoder interface reproduces encoder data and allows for serial data
transfer
for master/slave arrangements.
Figure E1
Picture of Analog Interface
E.3 Configurations
The Analog input and output options are available as follows:
INPUT
OUTPUT
Model #
CH1
CH2
CH1
CH2
5X
+/-10 V
+/-10 V
+/-10 V
+/-10 V
6X
0-20mA
0-20mA
0-20mA
0-
20mA
7X
+/-10 V
0-20mA +/-10 V
0-
20mA
Figure E2
Analog Configurations
Please consult Moog ICD Sales or a Moog Distributor for application specific ordering information.
The maximum input to each channel should not exceed 10 Volts for channels configured
for voltage or 20mA for channels configured for current.