CHAPTER 3.0 Wiring and Installation
3-22
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
3.6 Sequence of Component Wiring Recommendations
The following sequence for wiring is a recommendation. Individual wiring steps are denoted by a box character,
which can be used as an installation check off list.
The terminal block layout on all power supplies and servo-drives has been designed to isolate low voltage from
high voltage circuits. Cabinet conduits should be arranged to maintain this physical separation.
a) Power Circuit Wiring
Wire a 24V Logic Supply to the drive (Required on A size drives). Fit a suitable EMC filter on the 24V logic
Supply and fuse.
Wire a 24V Logic Supply to the drive for fan external supply, if necessary.
Wire a.c. mains input to user supplied fuses. Make a secure and reliable connection between the chassis of
the equipment and Earth.
Fit a suitable EMC Mains Line Filter after the User supplied fuses and contactor.
Wire a.c. mains from the user-supplied contactor to the power input poles of the DS2110.
b) Servo-drive Wiring
Plug in Axis I/O cable to J2 and connect other end to user I/O equipment.
Plug in resolver cable at J3 (or Encoder Cable to J4).
Connect appropriate communications cabling (RS232 at J1, and/or Field Bus).
c) Motor Wiring
Repeat the steps listed in this Section for each motor in the system.
Plug in and screw tight resolver/encoder cable to motor position connector.
Plug in and screw tight motor power cable to motor power connector. Also connect the brake terminations at
J2D (if provided).