CHAPTER 2.0 Safety & EMC Instructions
2-7
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
The following table details the recommended cable dimensions for all DS2110 models
DS2110 Models
Notes
µA A B
Cable
3/9
AWG
(mm
2
)
6/22
AWG
(mm
2
)
8/22
AWG
(mm
2
)
10/42
AWG (mm
2
)
14/42
AWG (mm
2
)
Line Power
3x14 (2.1)
3x12 (3.3)
Protective Bonding Cable
1x 6 (13)
Motor Power Cable
4x14 (2.1)
4x12 (3.31)
Shielded
Regen Resistor Cable
2x14 (2.1)
Shielded
DC Bus Cable
2x14 (2.1)
Shielded
Safety Interlock (If
applicable)
2x22 (0.3)
Shielded
24V Power Cable
2x14 (2.1)
Shielded
Note: 2x14 (2.08) = Number of conductors x conductor size (AWG = American wire gauge)
DS2110
Models
Notes
C D
Cable
20/45
AWG
(mm
2
)
25/70
AWG
(mm
2
)
30/90
AWG
(mm
2
)
50/140
AWG (mm
2
)
60/180
AWG (mm
2
)
Line Power
3x8 (8.4)
3x 6 (13)
3x 4 (21)
Protective Bonding Cable
1x 6 (13)
1x6 (13)
1x4 (21)
Motor Power Cable
4x8 (8.4)
4x6 (13)
4x4 (21)
Shielded
Regen Resistor Cable
2x8 (8.4)
2x 6 (13)
2x4 (21)
Shielded
DC Bus Cable
2x8 (8.4)
2x 6 (13)
2x4 (21)
Shielded
Safety Interlock (If
applicable)
2x22 (0.3)
Shielded
24V Power Cable
2x14 (2.1)
Shielded
DS2110 Models
Notes
E
Cable
100/240
AWG (mm
2
)
Line Power
3 x 1 (42)
Protective Bonding Cable
1 x 1 (42)
Motor Power Cable
4 x 1 (42)
Shielded
Regen Resistor Cable
2 x 2 (34)
Shielded
DC Bus Cable
2 x 1 (42)
Shielded
Safety Interlock (If applicable)
2x22 (0.3)
Shielded
24V Power Cable
2 x 14 (2.1)
Shielded
Table 2 - DS2110 Cable Dimensions