CHAPTER 3.0 Wiring and Installation
3-51
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
3.11.2 General Purpose Description of the Digital Outputs
The DS2110 provides 4 digital outputs on connector J2B & J2C. Only the digital outputs on J2B are detailed here.
-
Fixed connector: 5 pins, male connector
-
Mating connector, 5 pins spring cage, female, supplied with the drive. Phoenix Contact (Part # FK-MC 0.5/5-
ST-2.5)
-
Wiring: cable. 28-20AWG (0.14-0.5mm
2
)
-
Wire stripping: 8 mm
Pos. Name Function
J2B.1
Ext 24V DC
+24V Digital Output Supply
J2B.2
O1
Digital Output #1
User Configurable
J2B.3
O2
Digital Output #2
User Configurable
J2B.4
O3
Digital Output #3
User Configurable
J2B.5
Ext 24V Ret
Digital Output Return
Table 3. -25 J2B, DS2110 Digital Output connector
The following electrical description applies to all, except one, of the digital outputs of the DS2110. (One digital
output, Drive Ready, uses a relay rather than an opto-coupler).
EXT 24VDC
LOAD
EXT 24VDC
RETURN
EXT 24VDC
D01-D03
OPTOCOUPLER
ISOLATION
Figure 3.44 DS2110 Generic Digital Outputs
Note that:-
Voltage Range
is
6V to 32V
from Digital-Output to the O_COMMON line. Digital outputs switch only DC
voltages.
Output current
≤
250 mA, off state leakage current
≤
100 µA at 0 V.
Short circuit
protected, inductive load driving capability, reverse polarity protected. Protected for supply
voltage range of -40 V to +40 V.
All digital outputs are optically isolated
for noise immunity purposes. All DS2110 digital outputs are
isolated from high voltage circuitry.
Current flowing
in the digital output implies the function is active.