APPENDIX F – DEVICENET
TM
MEZZANINE CARD
F-11
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
jogging
JOG_SPEED
65273
f32
0
- FLT_MAX
FLT_MAX
0x74
0x4A Jog Speed
JOG_ACC
65274
f32
0
0
FLT_MAX
0x74
0x4B Acceleration time during Jog
JOG_DEC
65275
f32
0
0
FLT_MAX
0x74
0x4C Decceleration time during Jog
ACT_POS
65300
f32
0
- FLT_MAX
FLT_MAX
0x75
0x01 Actual Position
ACT_VEL
65301
f32
0
- FLT_MAX
FLT_MAX
0x75
0x02 Actual Rod Speed
ACT_FORCE 65302
f32
0
-
FLT_MAX
FLT_MAX 0x75
0x03
Actual
Force
FAULT_STATUS 65303
u32
0
0
ULONG_MAX
0x75
0x04 Current Fault status
GUI_DRIVE_ENABLE
65304
u16
0
0
1
0x75
0x05 GUI Command: Drive Enable
GUI_JOG_EXTEND_CMND
65305
u16
0
0
1
0x75
0x06 GUI Command: Jog Extend
GUI_JOG_RETRACT_CMND
65306
u16
0
0
1
0x75
0x07 GUI Command: Jog Retract
GUI_PROFILE_SELECT
65307
u16
0
0
7
0x75
0x08 GUI Command: Profile Select
GUI_START_CMND
65308
u16
0
0
1
0x75
0x09 GUI Command: Start Motion
GUI_STOP_CMND
65309
u16
0
0
1
0x75
0x0A GUI Command: Stop Motion
GUI_FAULT_RESET_CMND
65310
u16
0
0
1
0x75
0x0B GUI Command: Stop Motion
ANALOG_INPUT1_OFFSET
65311
s16
0
-32767
32767
0x75
0x0C Analog Input 1 offset
ANALOG_INPUT1_FULLSCALE
65312
f32
32768
-65535
65535
0x75
0x0D Analog Input 1 Fullscale
ACTUATOR_CENTER_POSITION 65313 f32
0 -
FLT_MAX FLT_MAX
0x75
0x0E
Actuator Center Position - For
lubrication
GUI_CENTER_ACTUATOR 65314
u16
0
0
1
0x75
0x0F GUI Command: Center Actuator
ANALOG_OUTPUT1_OFFSET 65315
f32
32768 -65535 65535
0x75
0x10 Analog output 1 offset
ANALOG_
OUTPUT1_FULLSCALE
65316
f32
32768
-65535
65535
0x75
0x11 Analog Input 1 Fullscale
FIELDBUS_
POS_SCALE_FACTOR 65520
f32
1
0 1
0x75
0x15
Scale Factor for scaling Move 1
Position when using field bus:
Target Position = Move 1
Position * Scale Factor
FIELDBUS_
VEL_SCALE_FACTOR
65521 f32
1
0
1 0x75
0x16
Scale Factor for scaling Move 1
Velocity when using field bus:
Target Velocity = Move 1
Velocity * Scale Factor
FIELDBUS_
FORCE_SCALE_FACTOR
65522 f32
1
0
1 0x75
0x17
Scale Factor for scaling Move 1
Max. Peak Force when using
field bus: Max Force = Max Peak
Force * Scale Factor
FIELDBUS_
65523
f32
1
0
1
0x75
0x18 Scale Factor for scaling Move 1