CHAPTER 3.0 Wiring and Installation
3-50
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
3.11.1 General Purpose Description of the Digital Inputs
The DS2110 provides 8 digital inputs on connector J2A.
-
Fixed connector: 9 pins, male connector
-
Mating connector, 9 pins spring cage, female, supplied with the drive. Phoenix Contact (Part # FK-MC 0.5/9-
ST-2.5)
-
Wiring: cable. 28-20AWG (0.14-0.5mm
2
)
-
Wire stripping: 8 mm
Pos. Name Function
J2A.1
I1
Digital Input # 1
Drive Enable
J2A.2
I2
Digital Input # 2
User Configurable
J2A.3
I3
Digital Input # 3
User Configurable
J2A.4
I4
Digital Input # 4
User Configurable
J2A.5
I5
Digital Input # 5
User Configurable
J2A.6
I6
Digital Input # 6
User Configurable
J2A.7
I7
Digital Input # 7
User Configurable
J2A.8
I8
Digital Input # 8
User Configurable
J2A.9 RET
Digital
Input
Ground
Table 3. -24 J2A, DS2110 Digital Input connector
The following electrical description applies to all the digital inputs of the DS2110.
+5V
4K7
Digital Input I1-I8
SIGNAL
Optocoupler
RET
3V3
Figure 3.43 DS2110 Generic Digital Inputs
Note that:-
Input Impedance
> 5k ohm
.
Voltage Range is
12V to 32V
from Digital-Input to the I_COMMON line. Inputs are protected for input voltages
from –40V to +40V
Input voltages whose magnitude is less than 12V with respect to the I_COMMON line will not be
guaranteed to be recognised as an
active
signal input.
Input voltages whose magnitude is more than 5V with respect to the I_COMMON line will not be
guaranteed to be recognised as an
inactive
signal input
All digital inputs are optically isolated
for noise immunity purposes. All DS2110 digital inputs are isolated
from high voltage circuitry internally
Current flowing
in the digital input implies the
'safer'
of the corresponding active/inactive functions. For
example, when current flows in the clockwise limit switch input, then the limit is NOT active.