CHAPTER 3.0 WIRING AND INSTALLATION
A-5
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
A.1.6 Data logger parameters
Paramete
r
Name
Field
Numb
er
Data Ty
pe
A
cce
s
s
Default
Value
Minimum
Value
Maxim
u
m
Value
Units
Storage
T
Data G
roup
data_logger_sample_frequency 1751
u32
R
9920 -
- Freq.
units
N
A
data_logger_divider_factor 1750
u16
R/W
1
1
-
None
N
A
data_logger_memory_size
1752 s16
R/W
500
500 8000 None
N
A
data_logger_enable 1753
u08
R/W
0,0,0,0
-
-
None
N
A
data_logger_channel 1754
u16
R/W
1000,1000,
1000,1000
- - None
N
A
A.1.7 Trigger parameters
Paramete
r
Name
Field
Numb
er
Data Ty
pe
A
cce
s
s
Default
Value
Minimum
Value
Maxim
u
m
Value
Units
Storage
T
Data G
roup
trigger_mode 1755
u08
R/W
0x03
-
0x03
None
N
A
trigger_field_number 1756
fld
R/W
1000
-
-
None
N
A
trigger_coupling 1757
u08
R/W
0x01
-
0x02
None
N
A
trigger_slope 1758
u08
R/W
0x01
0x01
0x03
None
N
A
trigger_level_8-bit 1759
u08
R/W
-
-
-
None
N
A
trigger_level_16-bit 1760
u16
R/W
-
-
-
None
N
A
trigger_level_24-bit 1761
u24
R/W
-
-
-
None
N
A
trigger_level_32-bit 1762
u32
R/W
-
-
-
None
N
A
trigger_level_float 1763
f32
R/W
-
-
-
None
N
A
trigger_level_double 1764
f64
R/W
-
-
-
None
N
A
trigger_delay 1765
s16
R/W
-
-
-
None
N
A
trigger_status 1767
u08
R
-
-
-
None
N
A