APPENDIX B – GUI
B-51
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
B.2.16.57 Drive Status Byte 2
DRIVE STATUS BYTE 2 :
•
Enable Attempted
→
Indicates that an attempt was made to enable the drive when the conditions for enabling
were not valid (e.g. hardware enable false).
•
Encoder Supply
→
Indicates an encoder supply fault.
•
Motor Thermal Foldback Warning
→
Indicates that the temperature is within 10% of the start temperature for
motor thermal foldback
•
Bridge Thermal Foldback Warning
→
Indicates that the temperature is within 10% of the start temperature for
bridge thermal foldback
B.2.16.58 Drive Status Byte 3
DRIVE STATUS BYTE 3 :
•
Drive OK
→
Shows the drive resources state. Drive resources are those that would be exclusive to a single
axis in a multi-axis drive.
•
Position Error in Limits
→
Indicates that the actual position has attained the target position within a
programmable range. Valid in position mode only.
•
Thermal Limiting
→
Indicates whether the thermal limiting is active.