CHAPTER 4.0 Getting Started
4-17
CDS7324 (FORMERLY LSF-0819)
Rev. A
INSTALLATION & USER’S MANUAL
4.15.3 Step Response With Velocity p-gain = 0.01 & i-gain = 0.0
The following step responses were obtained using a G464-804 Global motor with resolver feedback and under
no-load conditions.
Click
enable
button
( )
The Oscilloscope should trigger and the status prompt should turn red and read “
Stopped”
Disable drive using disable button
( )
.
Figure 4.16 Step Response With Velocity p-gain = 0.01 & i-gain = 0.0