533
Condition data error
■
Description
• The condition setting values are not set or
outside the setting range.
• The condition operator setting values are not set
or outside the setting range.
• The condition operator is a bit operator, and the
parameter 1 is 32 or more.
• An unusable condition operator is set for the set
condition.
• The conditional operator has been [parameter 1
> parameter 2] with 05H (P1
**
P2).
• The value in 'address' is out of the setting range
when the condition target is set to 'Buffer memory
(1-word/2-word)'. (1-word: 0 to 32767, 2-word: 0
to 32766)
■
Operation status at error occurrence
The system stops operation.
■
Action
Normalize the block start data.
■
Buffer memory address
534
Special start instruction
error
■
Description
No applicable special start instruction is present.
■
Operation status at error occurrence
The system stops operation.
■
Action
Correct the special start instruction code. (
■
Buffer memory address
■
Setting range
<Special start instruction>
00H to 06H
535
Circular interpolation not
possible
■
Description
The circular interpolation or helical interpolation is
carried out for the axis with the "degree" unit
setting.
■
Operation status at error occurrence
The system stops operation.
■
Action
Correct the control system. (
■
Buffer memory address
536
M code ON signal ON
start
■
Description
The positioning start is carried out when an M code
ON signal (X4 to X7) is turned ON.
■
Operation status at error occurrence
At start: The system will not operate.
■
Action
After turning OFF the M code ON signal, start the
system. (
■
Buffer memory address
Axis 1: 1504
Axis 2: 1604
Axis 3: 1704
Axis 4: 1804
■
Setting range
M code OFF request
1: The M code ON signal turns OFF.
537
PLC READY OFF start
■
Description
The positioning start is carried out when the PLC
READY signal (Y0) is turned OFF.
■
Operation status at error occurrence
At start: The system will not operate.
■
Action
Check the program which turns ON/OFF the PLC
READY signal (Y0), and turn ON the PLC READY
signal. Then start the system.
538
READY OFF start
■
Description
The positioning start is carried out when the LD75
READY signal (X0) is turned OFF.
■
Operation status at error occurrence
At start: The system will not operate.
■
Action
Check the LD75 READY ON signal, and then
start the system. (
543
Outside start No. range
■
Description
• At the start of positioning, the setting value of the
"positioning start No." of the axis control data is
outside the ranges of 1 to 600, 7000 to 7004, and
9001 to 9004.
• At a Pre-reading start, the "positioning start No."
setting of the axis control data is other than 1 to
600.
■
Operation status at error occurrence
At start: The system will not operate.
■
Action
Normalize the positioning start No. (
■
Buffer memory address
Axis 1: 1500
Axis 2: 1600
Axis 3: 1700
Axis 4: 1800
■
Setting range
Positioning start No.: 1 to 600, 7000 to 7004,
9001 to 9004
Classification
of errors
Error
code
Error name
Operation status at error occurrence
Action/Related buffer memory address/Set
range (Setting with program)
Summary of Contents for MELSEC-L LD75D
Page 2: ......
Page 11: ...9 Memo ...
Page 176: ...174 ...
Page 264: ...262 ...
Page 266: ...264 ...
Page 267: ...265 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 268: ...266 ...
Page 269: ...267 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 270: ...268 ...
Page 271: ...269 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 272: ...270 Z ABRST1 instruction execution ...
Page 273: ...271 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 278: ...276 ...
Page 279: ...277 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 280: ...278 ...
Page 281: ...279 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 282: ...280 ...
Page 283: ...281 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 284: ...282 ...
Page 285: ...283 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 286: ...284 ...
Page 287: ...285 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 316: ...314 Memo ...
Page 685: ...683 APPENDICES A Appendix 1 Function Update Appendix 1 1 Function comparison Memo ...
Page 738: ...736 Memo ...
Page 817: ......