![Mitsubishi Electric MELSEC-L LD75D User Manual Download Page 329](http://html.mh-extra.com/html/mitsubishi-electric/melsec-l-ld75d/melsec-l-ld75d_user-manual_238753329.webp)
327
CHAPTER 8 OPR CONTROL
8
8.
2 Mac
hine
O
P
R
8.2.5
OPR method (3): Stopper method 2)
The following shows an operation outline of the "stopper method 2)" OPR method.
(1) Operation chart
1.
The machine OPR is started. (The machine begins the acceleration designated in "[Pr.51] OPR
acceleration time selection", in the direction designated in "[Pr.44] OPR direction". It then moves
at the "[Pr.46] OPR speed" when the acceleration is completed.)
2.
The machine begins decelerating when the near-point dog ON is detected.
3.
The machine decelerates to the "[Pr.47] Creep speed", and subsequently moves at that speed.
(Torque limiting is required at this time. If the torque is not limited, the servomotor may fail in step
4).)
4.
The machine presses against the stopper at the creep speed and stops.
5.
The pulse output from the LD75 will stop at the zero signal after the machine stops, outputting the
"deviation counter clear output" to the drive unit. (A "deviation counter clear signal output time" is
set in [Pr.55].)
6.
After a "deviation counter clear signal" is output to the drive unit, the OPR complete flag ([Md.31]
Status: b4) turns from OFF to ON and the OPR request flag ([Md.31] Status: b3) turns from ON to
OFF.
1.
2. 3. 4. 5. 6.
ON
OFF
ON
OFF
OFF
ON
ON
OFF
0
t
OPR speed
Creep speed
Valid torque limit range
Torque limit
Standing by
In OPR
Standing by
Inconsistent
Movement amount after
near-point dog ON
Inconsistent
Value the machine moved is stored
OP address
Inconsistent
Torque limit setting value
OPR torque limit value
Current feed value
V
Near-point dog
Stops at stopper
Zero signal
Deviation counter clear output
OPR request flag
OPR complete flag
Md.31
Md.31
Md.26
Md.34
Torque limit stored value
Md.35
Md.20
Md.21
Pr.46
Pr.47
Pr.55
Machine feed value
Machine OPR start
(Positioning start signal)
[Y10,Y11,Y12,Y13]
Status : b3
Status : b4
Axis operation status
Deviation counter clear
signal output time
Summary of Contents for MELSEC-L LD75D
Page 2: ......
Page 11: ...9 Memo ...
Page 176: ...174 ...
Page 264: ...262 ...
Page 266: ...264 ...
Page 267: ...265 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 268: ...266 ...
Page 269: ...267 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 270: ...268 ...
Page 271: ...269 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 272: ...270 Z ABRST1 instruction execution ...
Page 273: ...271 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 278: ...276 ...
Page 279: ...277 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 280: ...278 ...
Page 281: ...279 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 282: ...280 ...
Page 283: ...281 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 284: ...282 ...
Page 285: ...283 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 286: ...284 ...
Page 287: ...285 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 316: ...314 Memo ...
Page 685: ...683 APPENDICES A Appendix 1 Function Update Appendix 1 1 Function comparison Memo ...
Page 738: ...736 Memo ...
Page 817: ......