![Mitsubishi Electric MELSEC-L LD75D User Manual Download Page 625](http://html.mh-extra.com/html/mitsubishi-electric/melsec-l-ld75d/melsec-l-ld75d_user-manual_238753625.webp)
623
CHAPTER 14 DEDICATED INSTRUCTIONS
14
1
4
.3
Z.
AB
R
S
T
1
,
Z.A
B
R
S
T2
, Z.
AB
R
S
T
3
,
Z.A
B
R
S
T4
(4) Errors
(a) When a dedicated instruction is completed abnormally, the error complete signal
((D)+1) is turned ON, and the error code is stored in the complete status ((S)+1).
Check and take measures against the error referring to
(5) Precautions
(a) After the absolute position detection system is configured, the absolute position
restoration must be carried out at least once after the power is turned ON or reset.
Unless the absolute position restoration of the LD75 is completed, the servo
amplifier will not be turned ON.
(b) Execute absolute position restoration when the PLC READY signal [Y0] is OFF.
(c) The restoration of the absolute position (Z.ABRST
instruction execution) can also
be carried out when the servo amplifier is turned ON.
If this is carried out, however, the servo ON signal is turned OFF for approx. 60ms + scan time (servo OFF) and
the motor may move. When carrying out the absolute position restoration during servo OFF, install an
electromagnetic brake and output the Z.ABRST instruction to that brake during the Z.ABRST
instruction
execution.
(d) The following dedicated instructions cannot be executed simultaneously for the
same axis. (Can be executed simultaneously for different axes.)
• Positioning start instructions (ZP.PSTRT1 to ZP.PSTRT4)
• Absolute position restoration instructions (Z.ABRST1 to Z.ABRST4)
• Teaching instructions (ZP.TEACH1 to ZP.TEACH4)
(e) If the Z.ABRST
instruction is executed in the following cases, an error "Dedicated
instruction error" (error code: 804) will occur and absolute position restoration
cannot be carried out.
• Any value other than 0 is set to "Status" (device: (S)+4) of the control data (at communication start with servo
amplifier).
• The instruction for a non-existent axis is specified. (Example: The Z.ABRST2 instruction is specified when
the LD75P1 is used.)
• "Status" (device: (S)+4) of the control data is changed during absolute position restoration (during
communication with servo amplifier).
Summary of Contents for MELSEC-L LD75D
Page 2: ......
Page 11: ...9 Memo ...
Page 176: ...174 ...
Page 264: ...262 ...
Page 266: ...264 ...
Page 267: ...265 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 268: ...266 ...
Page 269: ...267 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 270: ...268 ...
Page 271: ...269 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 272: ...270 Z ABRST1 instruction execution ...
Page 273: ...271 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 278: ...276 ...
Page 279: ...277 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 280: ...278 ...
Page 281: ...279 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 282: ...280 ...
Page 283: ...281 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 284: ...282 ...
Page 285: ...283 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 286: ...284 ...
Page 287: ...285 CHAPTER 6 PROGRAM USED FOR POSITIONING CONTROL 6 6 4 Positioning Program Examples ...
Page 316: ...314 Memo ...
Page 685: ...683 APPENDICES A Appendix 1 Function Update Appendix 1 1 Function comparison Memo ...
Page 738: ...736 Memo ...
Page 817: ......