225
Is the color changed by the heat?
Replace the damaged components
Replace the entire drive if necessary.
○
Any dust collection or stain?
Affix the terminal block cover
Remove the dust with a vacuum
cleaner
Replace components if cleaning is not
possible.
○
9.2.5 Main Circuit
Inspection Points
Corrective Action
Inspection Cycle
Daily
6
months
12
months
Are the screws all tightened?
Replace the damaged screws or
terminals if tightening is not possible.
○
Any shape change, crack, damage or
color change at the components or
insulators because of heat?
Replace the entire drive if the board is
impossible to be repared or replaced.
○
Any dust collection or stain?
Remove the foreign material and dust.
○
9.2.6 Main Circuit- Terminals & Cables
Inspection Points
Corrective Action
Inspection Cycle
Daily
6
months
12
months
Any shape or color change at the
terminals or jumper because of heat?
Repair or replace damaged wire
○
Any damage or color change at the
cables?
Repair or replace the damaged cables.
○
9.2.7 Main Circuit- Capacitors
Inspection Points
Corrective Action
Inspection Cycle
Daily
6
months
12
months
Any liquid leakage, color change, crack
or swell?
Replace the entire drive if the
component is impossible to be
replaced.
○
Has the cap come off or swellen?
○
Measure the Capacitance if necessary
○
Summary of Contents for EVO 6800 Series
Page 1: ...MANUAL Compact Vector Drive EVO 6800 Series...
Page 33: ...33 34 2 36 0 2 8 93 0...
Page 35: ...35 4 2 Main Circuit...
Page 41: ...41 4 3 Control Circuit...