115
Output
frequency
Bias
Up 2
command
Bias value is increased in steps as
defined in d4-02
Drive uses accel/decel times as
set in d4-02
Less
than 2s
Less
than 2s
More
than 2s
Figure 6.39 Up 2/Down 2 Bias when L4-01
>
0.0 Hz
L4-02
Frequency Command Acc./Dec Setting ( Up / Down 2)
Sets the acceleration/deceleration times to increase or decrease the frequency command bias
for Up/Down 2.
No.
Name
Setting
Range
Default
L4-02
Frequency Command Acc./Dec Setting ( Up2 / Down 2)
0, 1
0
0 : Current Acc./Dec. Time
The drive uses the currently active acceleration or deceleration time.
1 : Acc./Dec. Time 4
The drive uses the C1-06 (Acceleration Time 4) and C1-07 (Deceleration Time 4).
L4-03
Up/Down Frequency Command Save
No.
Name
Setting Range
Default
L4-03
Up/Down Frequency Command Save
0.00 to <1>
0.00 Hz
<1> The upper limit is determined by the values set to d1-02 (Maximum Output Frequency), d1-13 (Motor 2
Maximum Output Frequency) and L2-00 (Frequency Command Upper Limit).