114
Output
frequency
Bias
Up 2
command
Bias value is increased
using the acc./dec.times
set to L4-02
Figure 6.38 Up 2/Down 2 Bias when L4-01=0.0 Hz
Setting L4-01 ≠ 0.00 Hz
If the Up 2 or Down 2 command is closed for less than 2 seconds, the bias is increased or
decreased using the acceleration and deceleration times defined by L4-01 (
Frequency Command
Bias
). If the Up 2 or Down 2 command is closed for more than 2 seconds, the bias is increased
or decreased using the acceleration and deceleration times as Up 1/ Down 1. The frequency
command changes with the acceleration and deceleration times defined by L4-02 (Frequency
Command Acc./Dec Setting).