IP LDK-20 Programming Manual System Feature
39
Station COS
COS 1
There is no restriction to dial.
COS 2
Monitored by Exception Table A.
COS 3
Monitored by Exception Table B.
COS 4
Monitored by Exception Table A
& B.
COS 5
Long distance call is not allowed. (The dialed digits can be longer than 7 digits)
COS 6
Long distance call is not allowed. Only max. 7 digits may be dialed.
COS 7
Only intercom, paging and emergency call are allowed. No dialing allowed on CO Lines.
Operation
To store a number in a System Speed Dial from the system attendant,
1. Press the
[TRANS/PGM]
button.
2. Press the
[SPEED]
button.
3. Dial the system speed dial bin.
4. If desired, press the CO Line or Group button.
5. Dial the desired phone number and include these special codes.(max. 24 digits)
[CALLBK]
– Insert Pause
‘*’
– Display Security.
If it is stored as the first digit, its function is Display Security. Otherwise, its function is Pulse to
DTMF Switchover.
[DND/FOR]
– If CO Dial Tone Detect (see Ref.1) is set to ON and it is stored as the first or
second digit and the seized CO Line is behind PBX mode, its function is Dial Tone Detect.
Otherwise, its function is ‘*’.
[FLASH]
– Inserts a Flash into the speed number.
If seized CO Line is analog line, its function is Flash to PX (or PBX). If seized CO Line is
ISDN(
2.14
) line and it is stored as the first digit, it makes remaining digits sent with enveloped
not in calling party number IE but in keypad facility IE
6. Press the
[HOLD/SAVE]
button.
7. If desired, enter the name (Max. 12 characters) by dialing 2-digit for each character.
8. Press the
[HOLD/SAVE]
button.
* Note
: To store continuously, repeat the above procedure from 3.
To make a call using System Speed Dial from a DKTU,
1. Lift the Handset or press the
[MON]
button.
2. Press the
[SPEED]
button.
3. Dial the System Speed Dial bin.
To make a call using System Speed Dial from a SLT,
1. Lift the handset.
2. Dial the Speed Dial access code :
5 5 8
(see Ref.2).
3. Dial the System Speed dial bin.
Condition
1. The CPTU should be installed for dial tone detect.
2. System Speed Dial is restricted by Station COS.
3. There can be max. 24 digits in a system speed dial number including some digits and special
function codes.
Summary of Contents for IP LDK-20
Page 202: ...IP LDK 20 Programming Manual System Feature 186 ...
Page 211: ...IP LDK 20 Programming Manual System Feature 195 ...
Page 213: ...IP LDK 20 Programming Manual System Feature 197 ...
Page 472: ...IP LDK 20 Programming Manual ADMIN Programming 456 PROCEDURE 320 Value 2 Digit ...
Page 514: ...IP LDK 20 Programming Manual ADMIN Programming 498 ...