IP LDK-20 Programming Manual ADMIN Programming
378
4.5.3 SYSTEM TIMERS –
•
(PGM 182)
4.5.3.1 SLT Hook Switch Bounce Timer
Description
This timer is used at SLT only. Select the length of time that is needed to regard as a valid on-hook or
off-hook (for SLT).
Value : 01~25(2 digits)
PROCEDURE
+ 182 + + Value(100msec) +
4.5.3.2 SLT Maximum Hook Flash Timer
Description
This timer is used at SLT only. Select how long the user could press the hook switch in order for it to
be considered a FLASH (Timed-Break Recall) (for SLT)
Value : 001~250(3 digits)
PROCEDURE
+ 182 + + Value(10msec) +
4.5.3.3 SLT Minimum Hook Flash Timer
Description
This timer is used at SLT only. The minimum bound time that system considers as hook flash for SLT.
Value : 000~250(3 digits)
PROCEDURE
+ 182 + + Value(10msec) +