Starting up the device - PROFINET interface
Leuze electronic GmbH + Co. KG
CML 730i
129
If necessary, use the
wave function
to check that selection of the CML 700i is correct; e.g. in the
SIMATIC manager via the Search network dialog box in the
Edit Ethernet participants...
function.
Assign the individual device name to the MAC address.Alternatively, you can assign the IP address to
the MAC address.
From now on, and when programming, only the unique device name (max. 240 characters) is used.
At this point, assign another IP address (suggested by the control), a subnet mask and, if required, a
router address, and assign this data to the named participant (device name).
If the PROFINET device has a device name, the control assigns the IP address. If assignment of the IP
address is deactivated at the control, you have to assign the IP address to the device manually.
Check device name
After completing the configuration phase, check the device names that have been assigned.
SIMATIC Manager: [Search] button in the
Edit Ethernet participants...
function.
13.4 Parameter and process data with PROFINET
13.4.1 General information on PROFINET
In addition to the basic configurations (see chapter 8), the functionality of the CML 700i is defined via the
GSDML modules. The necessary modules are linked and appropriately configured for the given measure
-
ment application with a control-specific configuration software.
13.4.2 Module overview
The configuration parameters or process data for PROFINET are defined via the following module descrip
-
tions.
NOTICE
Assign unique device names!
Ensure that the device names are unique and that all participants are located in the same subnet.
The configuration tool, e.g. SIMATIC Manager, has normally already made sure of this.
NOTICE
Overwriting of data by PLC!
Note that the PLC overwrites the data set via the service interface.
During the interface-specific configuration phase, all interface-specific parameters changed via the
service interface are overwritten. This also applies for the parameters from modules that were not con
-
figured.
During the configuration phase, the CML 700i receives parameter telegrams from the control.
Before the parameter telegrams are evaluated and the respective parameter values are set, all inter
-
face-specific parameters are reset to default values. This ensures that the parameters of modules that
are not selected are set to the default values.
Module no.
Module name
Parame
-
ter
Input data Output
data
Device Access Point module (DAP-module) (see chapter 13.4.3)
0
0
0
Module 00
Sensor control module (see chapter 13.4.4)
0
0
2
Module 01
First interrupted beam (see chapter 13.4.5)
0
2
0
Module 02
First not interrupted beam (see chapter 13.4.6) 0
2
0
Module 03
Last interrupted beam (see chapter 13.4.7)
0
2
0
Module 04
Last not interrupted beam (see chapter 13.4.8) 0
2
0