Starting up the device - PROFIBUS interface
Leuze electronic GmbH + Co. KG
CML 730i
118
12.4.14 Extended settings (module 12)
12.4.15 Configuration of digital IOs (module 13)
The filter depth indicates the necessary number of consistent beam states before the evaluation
of the measurement values. All measurement values are accumulated and retained over the
duration of the integration time.
Parameter
Rel.
addr.
Data type
Value range
Default Explanation
Autoteach on power-on
0
Bit (7)
0 … 1
0 … 1
0
Automatic teach on power-on
0: Not active
1: Active
Key lock on the display
0
Bit(0)
0 … 1
0 … 1
0
0: Not active
1: Active
Filter depth
1
Unsigned8
1 … 255
1
The filter depth indicates the necessary number of consis
-
tent beam states before the evaluation of the measure
-
ment values. The filter depth corresponds to the number
of passes (measurement cycles) with interrupted beam so
that the result leads to switching.
Integration/hold time
2
Unsigned16
1 … 65535
1
All measurement values are accumulated and retained
over the duration of the integration time. Hold function in
ms.
Configuration of the inputs/outputs. The inputs/outputs can be set to positive switching (PNP) or
to negative switching (NPN). The switching behavior applies the same for all inputs/outputs.
Parameter
Rel.
addr.
Data type
Value range
Default Explanation
Switching level of digital I/Os
0
Bit (7)
0 … 1
0 … 1
1
0: Transistor, NPN
1: Transistor, PNP
Configuration of the inputs/outputs: pin 2 and/or pin 5.
Parameter
Rel.
addr.
Data type
Value range
Default Explanation
Configuration of pin 2
Pin 2 - Input/output selection
0
Bit (5)
0 … 1
0 … 1
1
0: Output
1: Input
Pin 2 - Switching behavior
0
Bit (4)
0 …
0 … 1
0
0: Light switching: HIGH
active
1: Dark switching: LOW active
Pin 2 - Input function
0
BitArea(2 … 3)
0-2
0 … 2
1
0: Not active
1: Trigger input
2: Teach input
Pin 2 - Output function
0
BitArea(0 … 1)
0 … 3
0 … 3
0
0: Not active
1: Switching output
(area 1 … 32)
2: Warning output
3: Trigger output
Pin 2 - Time module operating
mode
1
BitArea(4 … 7)
0 … 4
0 … 4
0
0: Not active
1: Start-up delay
2: Switch-off delay
3: Pulse stretching
4: Pulse suppression
Pin 2 - Delay time
2
Unsigned16
0 … 65535
0
Affects the selected function
of the time module.
Unit: ms