Starting up the device - Basic configuration
Leuze electronic GmbH + Co. KG
CML 730i
69
The display on the receiver control panel shows
Following a successful teach, the display switches back to the bar graph (alignment mode).
If teach is successful, both bars display the maximum value.
Figure 8.7: Display after successful teach
The next configuration step is to check the alignment.
8.3
Check alignment
Prerequisites:
• The light curtain must first be correctly aligned and a teach must be performed.
Check whether the green LEDs on the receiver control panel and transmitter illuminate continuously.
Use the bar graph indicator to check whether the light curtain is optimally aligned, i.e., whether the max
-
imum is reached for both the first beam (FB) and the last beam (LB) in the bar graph indicator.
Use the bar graph indicator to check the optimum alignment of the light curtain if you have corrected an
error that occurred.
The next configuration steps:
• Perform extended configurations on the receiver control panel if necessary (see chapter 8.5)
• Start up CML 700i light curtains with analog output (see chapter 9)
• Start up CML 700i light curtains with IO-Link interface (see chapter 10)
• Start up CML 700i light curtains with CANopen interface (see chapter 11)
• Start up CML 700i light curtains with PROFIBUS interface (see chapter 12)
• Start up CML 700i light curtains with PROFINET interface (see chapter 13)
• Start up CML 700i light curtains with RS 485 Modbus interface (see chapter 14)
8.4
Setting the function reserve
The function reserve can be set to four levels:
• High function reserve (low sensitivity)
• Medium function reserve
• Low function reserve (high sensitivity)
• Transparent objects
The function reserve can be set via the receiver control panel, via the respective fieldbus interface (see
chapter 10 et seq.) or via the
Sensor Studio
configuration software (see chapter 16).