Starting up the device - IO-Link interface
Leuze electronic GmbH + Co. KG
CML 730i
83
General configurations (group 4)
Device cycle time
68
5
(bit
offset
= 0)
unsigned 16
RO
1000
The device cycle time defines the duration of a
measurement cycle of the CML 700i.
Device model
90
0
unsigned 32
RW
1 … 6
1
Interfaces:
1: Reserved
2: Analog device with 2x inputs/outputs
3: IO-Link device with 4x inputs/outputs
4: CANopen device with 2x inputs/outputs
5: PROFIBUS device with 2x inputs/outputs
6: RS 485 Modbus device with 2x inputs/outputs
7: PROFINET device with 2x inputs/outputs
CANopen settings
91
0
record 16 bit,
isolated
access to
sub-index not
possible
CANopen settings allow setting of Node-ID and Bit
rate.
CANopen bit rate
91
1 (bit
offset
= 8)
unsigned 8
0 … 3
0
0: 1000 kbit/s
1: 500 kbit/s
2: 250 kbit/s
3: 125 kbit/s
CANopen node ID
91
2 (bit
offset
= 0)
unsigned 8
RW
1 … 127
10
PROFIBUS settings
92
0
record 32 bit,
isolated
access to
sub-index not
possible
PROFIBUS settings: bus address, bit rate
PROFIBUS bit rate
92
1 (bit
offset
= 8)
unsigned 8
0 … 3
6
0: 9.6 kbit/s
1: 19.2 kbit/s
2: 45.45 kbit/s
3: 93.75 kbit/s
4: 187.5 kbit/s
5: 500 kbit/s
6: 1500 kbit/s
7: 3000 kbit/s
Bus address
92
2 (bit
offset
= 8)
unsigned 8
RW
1 … 126
126
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
Configured under group 4 “General configurations” are the type of scanning (parallel-/diagonal-
/crossed-beam), counting direction and minimum object diameter for the evaluation (smoothing).
The minimum hole size for the evaluation, e.g., with web material, is configured via inverted
smoothing.