System commands (group 1)
CML 700i status information (group 2)
Group 13
Autosplitting (see page 91)
Group 14
Configuration for block evaluation of beam areas (see page 91)
Group 15
Evaluation functions (see page 93)
Group
Group name
The system commands trigger a direct action in the device.
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
System command
2
unsigned 8
WO
128, 130, 162,
163
128: Reset device
130: Factory reset
162: Perform teach
163: Save settings
Note:
Processing of the Save command takes up to
600 ms. During this time, no other data/telegrams
are accepted.
The status information consists of operating state information or error messages.
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
CML 700i status informa
-
tion
0
unsigned 16
RO
Bits 0 … 11: measurement cycle number of a
measurement;
Bits 12 … 13: reserved;
Bit 14: 1 = event (is set if the status changes)
Cause/reason for event can be seen in
index 2162.
Bit 15: 1 = valid measurement result exists
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
Teach status
69
0
unsigned 8
RO
0, 1, 128
0
Status information on teach event
0: Teach ok
1: Teach busy
128: Teach error
Alignment
70
0
record 32 bit,
isolated
access to
sub-index not
possible
RO
Information on the signal level of the first and last
beam. The value changes depending on the
selected function reserve.
Signal level of last beam
70
1
(bit
offset
= 16)
unsigned 16
RO
0
Signal level of first beam 70
2
(bit
offset
= 0)
unsigned 16
RO
0