Starting up the device - PROFINET interface
Leuze electronic GmbH + Co. KG
CML 730i
142
Example run 1:
Example run 2:
17
Reset hold function
-
18
Acknowledge teaching error
-
21
Reset error counter states
165
The argument must be passed
in order to execute the com
-
mand.
22
Permanently store error counter states
1234
The argument must be passed
in order to execute the com
-
mand.
Command no.
Description
Argument
Explanation
To execute the Reset error counter states and Permanently store error counter states com
-
mands, the argument is also to be defined (as PIN) in the receiver (Rx). This prevents an acci
-
dental triggering.
Output data
Input data
Trigger byte
Command
Argument
Meaning
Trigger echo
Command echo Response
Meaning
0x00
0x00
0x0000
Not used
0x00
0x00
0x0000
Not used
0x00
0x03
0x0000
Command pre
-
pared
0x00
0x00
0x0000
-
0x01
0x03
0x0000
Command trig
-
gered
0x00
0x03
0x0100
Receiver received
command.
0x01
0x03
0x0000
0x01
0x03
0x1000
Receiver (Rx) sent
confirmation (ACK).
0x00
0x03
0x0000
Reset trigger
0x00
0x00
0x0000
Trigger was reset,
waiting for next com
-
mand.
0x00
0x04
0x0000
Next command
prepared
0x00
0x00
0x0000
-
0x02
0x04
0x0000
Trigger com
-
mand
0x00
0x04
0x0100
Receiver received
command.
0x02
0x04
0x0000
0x02
0x04
0x2000
Receiver (Rx) sent
rejection (NACK)
because the com
-
mand is not known
or could not be exe
-
cuted.
0x00
0x04
0x0000
Reset trigger
0x00
0x00
0x0000
Trigger was reset,
waiting for next com
-
mand.
"0x" designates the corresponding entry as hexadecimal number. The actual entry consists only
of the following digits and is also only to be entered as such.
Changing the data value triggers a trigger for executing the command. Changing from a state >
0x00 to a state = 0x00 does not trigger a trigger!
Output data
Input data
Trigger byte
Command
Argument
Meaning
Trigger echo
Command echo Response
Meaning
0x00
0x00
0x0000
Not used
0x00
0x00
0x0000
Not used
0x00
0x11
0x0000
Command pre
-
pared
0x00
0x00
0x0000
Not used