Troubleshooting
Leuze electronic GmbH + Co. KG
CML 730i
197
Table 17.6:
Serious errors (cannot be corrected)
RxS 0x23F5 Configuration error – blanking.
Upper neighbor beam for beam “i” selected and no neigh
-
bor beam exists.
Check the configuration of
the blanking parameters
Reset device to factory set
-
tings.
RxS 0x23F6 Configuration error – blanking.
Lower neighbor beam for beam “i” selected and no neigh
-
bor beam exists.
Check the configuration of
the blanking parameters
Reset device to factory set
-
tings.
RxS 0x23F7 Configuration error – blanking.
Overlapping of the blanking areas.
Check the configuration of
the blanking parameters
Reset device to factory set
-
tings.
RxS 0x23F8 Configuration error – blanking.
Start beam > end beam.
Check the configuration of
the blanking parameters
Reset device to factory set
-
tings.
RxS 0x23FA Configuration error – time behavior.
The delay time is greater than the trigger cycle time/mea
-
surement cycle time.
Check the time behavior
setting (see chapter 20.2).
Reset device to factory set
-
tings.
RxS 0x23FB Configuration error – time behavior.
The pulse width is greater than the trigger cycle time.
Check the time behavior
setting (see chapter 20.2).
Reset device to factory set
-
tings.
RxS 0x23FC Configuration error – time behavior.
The measurement cycle time is greater than the trigger
cycle time.
Check the time behavior
setting (see chapter 20.2).
Reset device to factory set
-
tings.
Error code
Description
Measures
Error
Description
Measures
RxS 0x3003 Hardware error, receiver 5V supply
Return device following
consultation with Service
department (see
RxS 0x3005 Hardware error, receiver cascade
No receiver cascade or different LED number of transmitter
and receiver
RxS 0x3007 Hardware error, inter-controller communication interrupted
RxS 0x3008 Hardware error, different number of diodes at transmitter
and receiver
RxS 0x3009
RxS 0x300A
Hardware error, no Rx cascades
Hardware error, no Tx cascades
RxS 0x3100
RxS 0x3101
Error in the factory settings. Can only be rectified by repro
-
gramming the device firmware.