            Ultrasonic water Meter 

        DN15-DN40

 Instructions 

 

 

 

 

 

 

 

 

 
 
 

 

 

Important tips 

Before installing, please read this manual carefully. This manual is aimed at trained 

professionals; therefore, it does not include the basic installation steps. If there is any 
change in the product model and appearance, please refer to the actual product. This 
instruction applies equally to the case without affecting the function of the product. 
For details of the change, please contact the company. 

 

This  product  is  a  precision  measuring  instrument  ,  test  strictly  before  leaving 
factory, please operate by professional personnel. 

 

If the product  is  normal  operation  or  need to  be repaired, please contact  our 
company or our authorized dealers; 

 

This product is a precision measuring instrument, please do not throw it down or 
hit it; 

1

 

Product introduction 

1.1 Product features 

 

The low starting flow, minimum flow rate is lower than the 1/3 of the traditional 
water meter; 

 

Bi-directional flow measurement; 

 

The water temperature detection, temperature alarm;

 

 

 

No moving parts, no wear, can be long-term and stable operation;   

 

More than 10 years battery operated life span; 

 

Be  installed  at  any  angle,  the  measurement  accuracy  is  not  affected,

 

No  air 

measuring; 

 

Ultrasonic signal quality detection; 

 

Magnetic induction button; 

 

The overall IP68 design, long-term immersion in the work; 

 

To support M-Bus, RS485, infrared, wireless communication interface etc.; 

 

Be compatible with  GB/T  26831、CJ/T 188 and MODBUS  RTU communication 
protocol; 

 

The water meter is required in accordance with drinking water standards; 

 

LCD screen can be changed by touching the magnetic switch; 

 

SCF series(SCF15、SCF20、SCF25)are valve type.The valve can be controled on or 
off by command; 
 
 
 

1.2 Technical parameters and characteristics 

1.2.1 Technical Specifications 

1.2.2 Outputs

 

1.2.3 Flow Rate Performance Data   

1.2.4 Dimensions 

 

Note: * for the default length 

 

2 LCD 

2.1 Liquid crystal display interface 

 

There are two modes of display mode:

 

One is the standard menu display mode:; 

the other is a high precision menu display mode; 

 

switch between standard menu mode and high-precision menu mode by using 
the factory's meter reading software; 

 

Standard menu display is divided into single-screen menu display and ordinary 
menu display;   

 

With the magnetic switch can switch the same menu of the display items; 

 

Magnetic switch to use: with a magnetic pen touch the product LCD screen     

          icon position;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

Precision Class 

class 2 

Standards 

OIML R49, EN 14154, ISO4064 

Volume Display Options 

1. Net (Forward less reverse) 
2. Forward only 
3. Forward & reverse alternating 

Temperature grade 

T50(T30 optional) 

Pressure loss grade 

Δp40 

Power Source 

3.6V Li-battery: 10* years

 

Or additional power supply 

24VDC 

Environmental Protection 

IP68

 

(Additional 24VDC power supply, IP65) 

Ambient operation temp 

Class C (class B, class I optional) 

Maximum working pressure 

1.6MPa 

Range ratio  (q

p

:q

i

) 

250:1(80:1、100:1、160:1、400:1 500:1 optional) 

Data Logger 

Volumes:  480  Daily  data;36  Monthly  data;16  Yearly 
data 
Alarms data: 32

 

Maximum flow reading (m

3

Forward: 99999.99999;

 

reverse:-9999.99999 

Electromagnetic 

environment level 

Class E1(class E2 optional) 

* remark 

Battery  must  be  in  normal  amibent  temperature 
conditions,  also  depends  on  the  data  transmission 
frequency  and  correct  meter  battery  installation 
(positive electrode on the top) 

Standard    interface 

Infra-red、M-Bus、RS485 

Analog Output 

4~20mA:The  Analog  Output  shows  the  currently 
measured flow rate 

Wireless interface 

wM-Bus: T1 868MHz 

LoRa:470MHz 

NB-IoT 

GPRS 

Digital (pulse) Output 

OC: Volume 

Nominal diameter 

DN(mm) 

15 

20 

25 

32 

40 

Maximum flow Q

4

( m

3

/h) 

3.125 

7.875 

12.5 

20 

Common flow Q

3

( m

3

/h) 

2.5 

4.0 

6.3 

10.0 

16.0 

Boundary flux Q

2

( m

3

/h) 

0.016 

0.026 

0.04 

0.064 

0.102 

Minimum flow Q

1

( m

3

/h) 

0.01 

0.016 

0.025 

0.04 

0.064 

Pressure loss grade  Δp 

40 

40 

40 

40 

40 

Nominal 

diameter 

15 

20 

25 

32 

40 

L(mm) 

165/110 

* 

190/130/195 

* 

260/160/225 

* 

260/180/230 

* 

300/200/245 

* 

L1(mm) 

97 

97 

97 

97 

97 

L2(mm) 

259/204 

294/234/299 

380/280/345 

380/300/350 

428/328/373 

H(mm) 

91 

91 

91 

128 

139 

H1(mm) 

31 

28 

25 

29 

36 

W(mm) 

90 

90 

90 

90 

90 

Meter 

screw 

thread A

(inch) 

G

3

/

4

G1B 

G1

1

/

4

G1

1

/

2

G2B 

Threaded 

for union B

(inch) 

R

1

/

2

 

R

3

/

4

 

R1 

R1

1

/

4

 

R1

1

/

2

 

 

 