Starting up the device - PROFINET interface
Leuze electronic GmbH + Co. KG
CML 730i
125
13
Starting up the device - PROFINET interface
The configuration of a PROFINET interface involves the following steps on the receiver control panel and
in the control-specific configuration software.
General prerequisites:
• The measuring light curtain has been mounted (see chapter 6) and connected (see chapter 7) cor
-
rectly.
• The basic configuration has been performed (see chapter 8).
13.1 Checking the PROFINET basic configuration on the receiver control panel
The configurations of the communication parameters can be checked on the receiver control panel.
The structure of these configurations in the receiver control panel menu is as follows:
Process mode is configured via the control-specific PROFINET interface and the
Sensor Studio
configu
-
ration software (see chapter 16).
13.2 Configuring the PROFINET interface
The CML 700i is designed as a PROFINET IO device with real-time (RT) communication in conformance
class B. The device integrates a switch with two Fast Ethernet ports (100 Mbit/s) in accordance with
IEEE 802.3u (100 BASE-TX).The device supports full duplex operation as well as auto-negotiation and
auto-crossover.
• The functionality of the CML 700i is defined via parameters which are organized in modules. The
modules are part of the Generic Station Description Markup Language (GSDML) file.
• Each device has a unique MAC address (Media Access Control) that is specified on the name plate.
The MAC address (MAC-ID) is linked to an IP address during the course of configuration.
• The control-specific software for creation of PROFINET networks links the IP address to a freely
selectable device name which may only exist once in the network.
Address Link Label
The “Address Link Label” is an additional stick-on label that is affixed to the device.
Level 0
Level 1
Level 2
Description
Main Settings
Commands
Operation settings
IO-Link
PROFINET
Device name
IP address
Subnet mask
Gateway
MAC address
Read-only parameter – assigned dynamically by the control
Device-specific MAC address, as specified on the name plate