Starting up the device - IO-Link interface
Leuze electronic GmbH + Co. KG
CML 730i
89
Settings for digital switching outputs (group 11)
Input/output selection
83
1
(bit
offset
= 24)
unsigned 8
RW
0 … 1
0
0: Output
1: Input
Switching behavior
83
2
(bit
offset
= 16)
unsigned 8
RW
0 … 1
0
0: Normal - light switching
1: Inverted - dark switching
Input function
83
3
(bit
offset
= 8)
unsigned 8
RW
0 … 2
0
0: Not active
1: Trigger input
2: Teach input
Output function
83
4
(bit
offset
= 0)
unsigned 8
RW
0 … 3
0
0: Not active
1: Switching output (area 1 … 32)
2: Warning output
3: Trigger output
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
In this group, the beam areas can be mapped to the switching outputs and assigned a time func
-
tion.
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
Configuration of pin 2
Configuration of switch
-
ing output pin 2
84
0
record 56 bit,
isolated
access to
sub-index not
possible
RW
Four different time functions can be set. Max.
adjustable time period is 65 sec. Output has to be
assigned to a beam area 1 … 32.
Operating mode of time
module
84
1
(bit
offset
= 48)
unsigned 8
RW
0 … 4
0
0: Not active
1: Start-up delay
2: Switch-off delay
3: Pulse stretching
4: Pulse suppression
Time constant for
selected function
84
2
(bit
offset
= 32)
unsigned 8
RW
0 … 65,000
0
Unit: ms
Area mapping 32 … 25
84
3
(bit
offset
= 24)
unsigned 8
RW
0b000
00000
Area mapping 24 … 17
84
4 (bit
offset
= 16)
unsigned 8
RW
0b000
00000
Area mapping 16 … 9
84
5
(bit
offset
= 8)
unsigned 8
RW
0b000
00000
Area mapping 8 … 1
84
6
(bit
offset
= 0)
unsigned 8
RW
0b000
00001
......
....
....
..
..
..
.......
......
....
....
..
..
..
.......
Configuration pin 7
Digital Output Pin 7 Set
-
tings
87
0
record 56 bit,
isolated
access to
sub-index not
possible
RW
Four different time functions can be set. Max.
adjustable time period is 65 sec. Output has to be
assigned to a beam area 1 … 32.