Starting up the device - IO-Link interface
Leuze electronic GmbH + Co. KG
CML 730i
87
Teach settings (group 9)
Logical value for blanking
area 1
76
3
(bit
offset
= 176)
unsigned 16
RW
0 … 4
0
0: No beams blanked
1: Logical value 0 for blanked beams
2: Logical value 1 for blanked beams
3: Logical value = same as adjacent beam with
lower beam number
4: Logical value = same as adjacent beam with
higher beam number
Start beam of blanking
area 1
76
4
(bit
offset
= 160)
unsigned 16
RW
1 … 1774
1
End beam of blanking
area 1
76
5
(Bit
offset
= 144)
unsigned 16
RW
1 … 1774
1
Logical value for blanking
area 2
76
6
(bit
offset
= 128)
unsigned 16
RW
0 … 4
0
0: No beams blanked
1: Logical value 0 for blanked beams
2: Logical value 1 for blanked beams
3: Logical value = same as adjacent beam with
lower beam number
4: Logical value = same as adjacent beam with
higher beam number
Start beam of blanking
area 2
76
7
(bit
offset
= 112)
unsigned 16
RW
1 … 1774
1
End beam of blanking
area 2
76
8
(bit
offset
= 96)
unsigned 16
RW
1 … 1774
1
......
....
....
..
..
..
.......
......
....
....
..
..
..
.......
Logical value for blanking
area 4
76
12
(bit
offset
= 32)
unsigned 16
RW
0 … 4
0
0: No beams blanked
1: Logical value 0 for blanked beams
2: Logical value 1 for blanked beams
3: Logical value = same as adjacent beam with
lower beam number
4: Logical value = same as adjacent beam with
higher beam number
Start beam of blanking
area 4
76
13
(bit
offset
= 16)
unsigned 16
RW
1 … 1774
1
End beam of blanking
area 4
76
14
(bit
offset
= 0)
unsigned 16
RW
1 … 1774
1
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
In most applications, it is recommended that teach values be stored in non-volatile memory
(remanent).
Depending on the function reserve selected for the teach event, the sensitivity is higher or lower
(high function reserve = low sensitivity; low function reserve = high sensitivity).