Example configurations
Leuze electronic GmbH + Co. KG
CML 730i
172
15.5.4 Configuration of smoothing via PROFIBUS interface
Assign the desired value for smoothing.
Example: Smoothing of four interrupted beams
Example: Inverted smoothing of four interrupted beams
15.5.5 Configuration of smoothing via PROFINET interface
Assign the desired value for smoothing.
Example: Smoothing of four interrupted beams
Example: Inverted smoothing of four interrupted beams
15.5.6 Configuration of smoothing via RS 485 Modbus interface
Assign the desired value for smoothing
Example: Smoothing of four interrupted beams
Example: Inverted smoothing of four interrupted beams
15.6 Example configuration - Cascading
15.6.1 Configuration of a cascading arrangement (general)
The following figure shows an example for a timing sequence of a cascading arrangement with three light
curtains.
General configuration
(module 3)
Index 2100 sub 4:
= 4
Beams are taken into account in the evaluation once there are four or more
free beams
General settings
(module 11)
Parameter
Smoothing
:
= 4
Beams are taken into account in the evaluation once
there are four or more interrupted beams
General settings
(module 11)
Parameter
Inverted smoothing
:
= 4
Beams are taken into account in the evaluation once
there are four or more free beams
General settings
(module 30)
Parameter
Smoothing
:
= 4
Beams are taken into account in the evaluation once
there are four or more interrupted beams
General settings
(module 30)
Parameter
Inverted smoothing
:
= 4
Beams are taken into account in the evaluation once
there are four or more free beams
General settings/smoothing
(group 4)
Parameter
0x47 smoothing
Write access:
01 10 00 47 00 02 04 00 00 04 01 75 79
Response to write access:
01 10 00 47 00 02 F1 DD
General settings/smoothing
(group 4)
Parameter
0x47 smoothing
Write access:
01 10 00 47 00 02 04 00 00 01 04 B6 2A
Response to write access:
01 10 00 47 00 02 F1 DD