Connecting to a PC – Sensor Studio
Leuze electronic GmbH + Co. KG
CML 730i
192
If parameters are changed in the device manager (DTM) that affect other parameters (e.g., if
changing the beam mode causes the configured logical beams to change), the changes to these
parameters are configured in the device – but are not yet displayed in the
Sensor Studio
display.
Click on the [Synchronize with device] button (
) to synchronize the
Sensor Studio
display with
the current configuration of the light curtain. Following successful synchronization, the [Upload
device data set from device] button (
) is displayed in the device manager (DTM).
16.4.4
PROCESS
function
• The
Process
function offers graphical visualizations of the process data of the connected light cur
-
tain.
Figure 16.6: Graphical visualization: object position
• [Cyclical refresh] button (
): Starts the cyclical acquisition of the process data, which are graphi
-
cally depicted under
Numerical display
,
Beam-stream display
and Areas and outputs. Each graphical
display covers up to 300 seconds.
•
Beam-stream display
: Using the [Show or hide the graphical cursor] button (
), you can move the
graphical cursor in the visualization, e.g., to evaluate the time difference between two events.