Example configurations
Leuze electronic GmbH + Co. KG
CML 730i
181
Configure the digital IOs (pin 5) settings.
Configuring light curtain 3:
Configure the trigger settings (triggered, slave, delay time).
Configure the digital IOs (pin 5) settings.
Cascading configuration
(module 34)
Parameter
Cascading
= 1
Active
Note: With cascading operation, the master must also be set to 1 (active)!
Parameter
Function type
= 0
Slave - expects trigger signal
Parameter
Delay time
Trigger → Scan [µs]
Enter cycle time of light curtain 1 (LC1)
Digital IO1 (pin 5) settings
(module 32)
Parameter
Pin 5 - Input/
output selection
= 1
Input
Parameter
Pin 5 - Input/
output selection
= 0
Light switching
Parameter
Pin 5 - Input
function
= 1
Trigger In
Cascading configuration
(module 34)
Parameter
Cascading
= 1
Active
Note: With cascading operation, the master must also be set to 1 (active)!
Parameter
Function type
= 0
Slave - expects trigger signal
Parameter
Delay time
Trigger → Scan [µs]
Enter cycle time of light curtain 1 and light curtain 2 (= sum of cycle times of
light curtains LC1+LC2)
Digital IO1 (pin 5) settings
(module 32)
Parameter
Pin 5 - Input/
output selection
= 1
Input
Parameter
Pin 5 - Switch
-
ing behavior
= 0
Light switching
Parameter
Pin 5 - Output
function
= 1
Trigger In