Example configurations
Leuze electronic GmbH + Co. KG
CML 730i
170
15.4.4 Configuration of blanking areas via PROFIBUS interface
Perform blanking area activation and deactivation.
Example: automatic blanking of two areas during teaching
In the background, the configuration for blanking areas 01 and 02 is calculated and stored in non-volatile
memory. Upon successful teach completion, all other objects of the blanking configuration are stored in
non-volatile memory if the
Type of storage for teach values
parameter is set to value 0 = non-volatile
storage of teach values.
Example: Deactivation/resetting of auto blanking
15.4.5 Configuration of blanking areas via PROFINET interface
Perform blanking area activation and deactivation.
Example: automatic blanking of two areas during teaching
In the background, the configuration for blanking areas 01 and 02 is calculated and stored in non-volatile
memory. Upon successful teach completion, all other objects of the blanking configuration are stored in
non-volatile memory if the
Type of storage for teach values
parameter is set to value 0 = non-volatile
storage of teach values.
Example: Deactivation/resetting of auto blanking
15.4.6 Configuration of blanking areas via RS 485 Modbus interface
Perform blanking area activation and deactivation.
Example: automatic blanking of two areas during teaching
Blanking configuration
(module 16)
Parameter
Number of auto blanking areas
= 2
Two blanking areas permitted
Parameter
Auto blanking (during teaching)
= 1
Automatic blanking-area configuration active
Sensor control module
(module 0)
Change value of byte 2
Execute teach
Blanking configuration
(module 16)
Parameter
Number of auto blanking areas
= 0
No blanking areas permitted
Parameter
Auto blanking (during teaching)
= 0
Automatic blanking area configuration not active
Blanking configuration
(module 16)
Parameter
Log. value for blanking area 1
= 0
No beams blanked
Parameter
Log. value for blanking area 2
= 0
No beams blanked
Sensor control module
(module 0)
Change value of byte 2
Execute teach
Blanking configuration
(module 35)
Parameter
Number of auto blanking areas
= 2
Two blanking areas permitted
Parameter
Auto blanking (during teaching)
= 1
Automatic blanking-area configuration active
Sensor control module
(module 0)
Change value of byte 2
Execute teach
Blanking configuration
(module 35)
Parameter
Number of auto blanking areas
= 0
No blanking areas permitted
Parameter
Auto blanking (during teaching)
= 0
Automatic blanking area configuration not active
Blanking configuration
(module 35)
Parameter
Log. value for blanking area 1
= 0
No beams blanked
Parameter
Log. value for blanking area 2
= 0
No beams blanked
Sensor control module
(module 0)
Change value of byte 2
Execute teach