1. Make sure that the backplane or back plate is removed from the drive cage.
(See “Removing the backplane or back plate (3.5-inch drives)” on page 91 or
“Removing the SAS backplane (2.5-inch drives)” on page 94 for instructions,
as applicable.)
2. Line up the drive cage with the drive bays on the front of the server.
3. Push the drive cage into the server until it stops.
4. Align the holes in the top of the drive cage with the holes in the top of the
chassis; then, insert the screws that secure the drive cage to the chassis.
5. Install the backplane or back plate. (See “Installing the backplane or back plate
(3.5-inch drives)” on page 92 or “Installing the SAS backplane (2.5-inch
drives)” on page 94 for instructions, as applicable.)
6. Install the cover (see “Installing the cover” on page 61).
7. Install the hard disk drives.
8. Install the server in the rack.
9. Connect the cables and power cords.
10. Turn on all attached devices and the server.
Removing and replacing FRUs
FRUs must be installed only by trained service technicians.
The illustrations in this document might differ slightly from the hardware.
Microprocessor
The following notes describe the type of microprocessor that the server supports
and other information that you must consider when you install a microprocessor:
v
The server supports one Intel land grid array (LGA) 775-land dual-core
microprocessor. The type, speed, and L2 cache of the microprocessor depends
on the server model.
v
Read the documentation that comes with the microprocessor to determine
whether you have to update the BIOS code. To download the most current level
of BIOS code, go to http://www.lenovo.com/support.
v
The microprocessor uses an integrated voltage regulator on the system board.
98
ThinkServer RS110 Types 6435, 6436, 6437 and 6438: Hardware Maintenance Manual
Summary of Contents for ThinkServer RS110
Page 1: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 2: ......
Page 3: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 8: ...vi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 18: ...xvi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 74: ...56 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 251: ......
Page 252: ...Part Number 46U0856 Printed in USA 1P P N 46U0856 ...