Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, RS110 Types 6435, 6436, 6437 and 6438 server,” on page 27 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
1962
A hard disk drive does not contain a valid
boot sector.
1. Make sure that a startable operating system is
installed.
2. Run the hard disk drive diagnostic tests.
3. Reseat the following components:
a. Hard disk drive
b. Hard disk drive backplane cable or back plate
cables
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Hot-swap models) Hard disk drive cable
b. Hard disk drive
c. Hard disk drive backplane or back plate
d. (Trained service technician only) System
board
2462
Video configuration error.
Note:
This error code appears through the
console redirection remote video interface
only. The server VGA function has failed.
1. Make sure that a working monitor is connected
correctly to the server.
2. Run the Configuration/Setup Utility program and
load the default settings (see “Using the
Configuration/Setup Utility program” on page 17).
3. (Trained service technician only) Replace the
system board assembly.
3001
SMART failure predicted on hard disk drive.
Replace the hard disk drive.
3003
SMART command execution failure on hard
disk drive.
Replace the hard disk drive.
3005
Current hard disk configuration does not
support SMART function.
Replace the hard disk drive.
5962
Internal CD/DVD drive configuration
changed.
An expected CD or DVD drive was not
detected.
1. Run the Configuration/Setup Utility program and
load the default settings (see “Using the
Configuration/Setup Utility program” on page 17).
2. Reseat the following components:
a. CD or DVD drive cable
b. CD or DVD drive
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. CD or DVD drive cable
b. CD or DVD drive
c. (Trained service technician only) System
board
120
ThinkServer RS110 Types 6435, 6436, 6437 and 6438: Hardware Maintenance Manual
Summary of Contents for ThinkServer RS110
Page 1: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 2: ......
Page 3: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 8: ...vi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 18: ...xvi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 74: ...56 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 251: ......
Page 252: ...Part Number 46U0856 Printed in USA 1P P N 46U0856 ...