v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, RS110 Types 6435, 6436, 6437 and 6438 server,” on page 27 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
188
Remote Supervisor Adapter II SlimLine
EEPROM CRC #2 bad
1. Restart the server.
2. Update the BMC firmware.
3. Update the Remote Supervisor Adapter II
SlimLine firmware.
4. Replace the Remote Supervisor Adapter II
SlimLine.
5. (Trained service technician only) Replace the
system board.
189
Three attempts were made to access the
server with an incorrect password.
Restart the server and enter the administrator
password; then, run the Configuration/Setup Utility
program and change the power-on password.
289
A DIMM has been disabled by the system.
1. Make sure that the DIMM is installed correctly
(see “Installing a memory module (DIMM)” on
page 75).
2. Reseat the DIMM.
3. Replace the DIMM.
602
Invalid diskette boot record
1. Replace the diskette.
2. Reseat the diskette drive cables.
3. Replace the diskette drive.
1162
Serial port error
The I/O address of an added device
conflicts with the base addresses of the
serial port.
1. Run the Configuration/Setup Utility program and
make sure that the serial port settings are correct.
2. Run the Configuration/Setup Utility program and
change the I/O address of the added device so
that it does not conflict with the serial port
address.
3. (Trained service technician only) Replace the
system board.
1600
The baseboard management controller
failed BIST (built-in self-test).
1. Restart the server.
2. (Trained service technician only) Replace the
system board.
1601
The BMC is not responding.
Systems-management adapter
communication error.
1. Turn off the server and disconnect AC power from
the server; then, reconnect AC power.
2. Restart the server.
3. Make sure that the BMC heartbeat LED is
flashing.
4. Update the BMC firmware.
5. Update the BIOS code.
6. (Trained service technician only) Replace the
system board.
116
ThinkServer RS110 Types 6435, 6436, 6437 and 6438: Hardware Maintenance Manual
Summary of Contents for ThinkServer RS110
Page 1: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 2: ......
Page 3: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 8: ...vi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 18: ...xvi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 74: ...56 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 251: ......
Page 252: ...Part Number 46U0856 Printed in USA 1P P N 46U0856 ...