v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, RS110 Types 6435, 6436, 6437 and 6438 server,” on page 27 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
system event/error log message
Action
ASM reset was initiated by the user
Information only.
Configuration error recovery on the interconnect
network
Information only.
CPU over temperature.
1. Make sure that the fans have good airflow and are not
obstructed.
2. (Trained service technician only) Reseat the microprocessor
heat-exchanger assembly.
DASD controller removal
1. Check the following cables for damage. Make sure that the
cables are not broken, crimped, or caught by any components.
v
(Hot-swap models only) The cable from the SAS/SATA
controller to the hard disk drive backplane. If this cable is
damaged, replace the cable.
v
(Simple-swap models only) The cables from the hard disk
drive back plate to the SATA connectors on the system
board. If either of these cables is damaged, replace the back
plate.
v
The power cable or cables to the hard disk drive backplane
or back plate. If this cable is damaged, replace the power
supply.
2. Reseat the cables listed in step 1, restarting the server after
you have reseated all cables.
DHCP failure, no IP@ assigned-RETRYING!,
rc=
xxx
, count=
yyy
Information only.
Dialback failed for userid
x
. Could not connect at
phone number
yyy yyy yyyy
Information only.
ENET[
eee
] DHCP-HstNme=
a
, DN=
b
,
IP@=
ccc.ccc.ccc.ccc
GW@=
ddd.ddd.ddd.ddd
,
NMsk=
fff.fff.fff.fff
, DNS1@=
ggg.ggg.ggg.ggg
,
DNS2@=
hhh.hhh.hhh.hhh
Information only.
ENET[
eee
] IP-Cfg: HstName=
x
,
IP@=
ccc.ccc.ccc.ccc
, GW@=
ddd.ddd.ddd.ddd
,
NetMsk=
fff.fff.fff.fff
Information only.
Failure reading an I2C device, possible bus
failure.
1. Reseat the following components:
a. AC power cord
b. Power supply
2. (Trained service technician only) Replace the system board.
Fan
x
Outside Recommended Speed.
1. Make sure that fan
x
is not obstructed.
2. Reseat the following components:
a. Fan
x
b. Fan
x
cable
3. Replace fan
x
.
208
ThinkServer RS110 Types 6435, 6436, 6437 and 6438: Hardware Maintenance Manual
Summary of Contents for ThinkServer RS110
Page 1: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 2: ......
Page 3: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 8: ...vi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 18: ...xvi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 74: ...56 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 251: ......
Page 252: ...Part Number 46U0856 Printed in USA 1P P N 46U0856 ...