v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, RS110 Types 6435, 6436, 6437 and 6438 server,” on page 27 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
1805
PCI option ROM checksum error
1. Remove the failing adapter.
2. Reseat each adapter.
3. Reseat the riser-card assembly.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Each adapter
b. Riser-card assembly
c. (Trained service technician only) System
board
1806
PCI device failed built-in self-test (BIST)
1. If the error code indicates a particular PCI
Express slot or device, remove that device.
2. Reseat the following components:
a. Each adapter
b. Riser-card assembly
3. Replace the following components one at a time,
in the order shown above, restarting the server
each time.
a. Each adapter
b. Riser-card assembly
c. (Trained service technician only) System
board
1807
PCI device not found on system board
1. Make sure that no devices have been disabled in
the Configuration/Setup Utility program.
2. Reseat the following components:
a. Failing adapter (indicated by a lit LED), or
each adapter one at a time, restarting the
server each time, to isolate the failing adapter
b. Riser-card assembly
3. Remove both adapters from the riser-card
assembly.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Riser-card assembly
b. (Trained service technician only) System
board
Chapter 5. Diagnostics
119
Summary of Contents for ThinkServer RS110
Page 1: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 2: ......
Page 3: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 8: ...vi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 18: ...xvi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 74: ...56 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 251: ......
Page 252: ...Part Number 46U0856 Printed in USA 1P P N 46U0856 ...