v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, RS110 Types 6435, 6436, 6437 and 6438 server,” on page 27 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
1800
Unavailable PCI hardware interrupt.
1. Run the Configuration/Setup Utility program and
adjust the adapter settings.
2. Remove each adapter one at a time, restarting
the server each time, until the problem is isolated.
1801
An adapter has requested memory
resources that are not available
1. Run the Configuration/Setup Utility program and
make sure that sufficient memory is installed in
the server.
2. Run the Configuration/Setup Utility program and
disable some other resources to make more
space available.
3. If possible, change the order of the adapters in
the PCI Express slots so that the device that
requires the most memory resources is positioned
early in the scan order (see the
User Guide
for
information about the scan order).
4. Remove the adapter or disable BIOS on the
adapter to remove the request for memory
resources. See the documentation that comes
with the adapter for information about disabling
the adapter BIOS.
5. (Trained service technician only) Replace the
system board.
1802
No more I/O space is available for a PCI
device
1. Run the Configuration/Setup Utility program and
make sure that interrupt resource settings are
correct.
2. If the error code indicates a particular PCI
Express slot or device, remove that device.
3. If the error continues, reseat each adapter.
4. (Trained service technician only) Replace the
system board.
1803
No more memory available (above 1 MB)
1. If the error code indicates a particular PCI
Express slot or device, remove that device.
2. If the error continues, reseat each adapter.
3. (Trained service technician only) Replace the
system board.
1804
No more memory available (below 1 MB)
1. If the error code indicates a particular PCI
Express slot or device, remove that device.
2. If the error continues, reseat each adapter.
3. (Trained service technician only) Replace the
system board.
118
ThinkServer RS110 Types 6435, 6436, 6437 and 6438: Hardware Maintenance Manual
Summary of Contents for ThinkServer RS110
Page 1: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 2: ......
Page 3: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 8: ...vi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 18: ...xvi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 74: ...56 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 251: ......
Page 252: ...Part Number 46U0856 Printed in USA 1P P N 46U0856 ...