Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, RS110 Types 6435, 6436, 6437 and 6438 server,” on page 27 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
system event/error log message
Action
Fan
x
Failure
1. Make sure that fan
x
is not obstructed.
2. Reseat the following components:
a. Fan
x
b. Fan
x
cable
3. Replace fan
x
.
Flash of
x
via
y
failed for user
z...z
Information only.
Flash of
x
by
y
via
z
was successful..
w
Information only.
Flash succeeded for
x
(address :
y
)
Information only.
Hard drive
x
removal detected.
Reseat hard disk drive
x
and restart the server.
Hard drive
x
fault
1. Run the diagnostic programs.
2. Replace hard disk drive
x
.
3. Replace the hard disk drive backplane or back plate.
Internal error CPU fault
Information only. If the message remains:
1. (Trained service technician only) Reseat the microprocessor.
2. (Trained service technician only) Replace the microprocessor.
Invalid userid or password received. Userid is
x
Information only.
LAN: Command mode tamper triggered.
Possible break-in attempt
Information only.
LAN: Ethernet interface is no longer active
Information only.
LAN: Ethernet interface is now active
Information only.
LAN: Telnet tamper triggered. Possible break-in
attempt
Information only.
LAN: Web Server tamper delay triggered.
Possible break-in attempt
Information only.
No ISMP gateway defined for the interconnect
network. RSA
x
is assuming the gateway
Information only.
OS Watchdog response enabled by
x
Information only.
OS Watchdog response disabled by
x
Information only.
PFA Alert, see preceding error in system error
log.
Information only. See the preceding entry in the system-error log.
Possible ASM reset occurred --- reason
unknown
Information only.
Power off
Information only.
Power on
Information only.
PPP_1: Client connected at
nnnn
bps
Information only.
PPP_1: User requested to abort PPP interface
Information only.
Chapter 5. Diagnostics
209
Summary of Contents for ThinkServer RS110
Page 1: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 2: ......
Page 3: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 8: ...vi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 18: ...xvi ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 74: ...56 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer RS110 Types 6435 6436 6437 and 6438 Hardware Maintenance Manual ...
Page 251: ......
Page 252: ...Part Number 46U0856 Printed in USA 1P P N 46U0856 ...