Repairs, maintenance and settings by technicians
22
Checking/setting sensor B22 “Bale on table” 22.20
BiG Pack 1270
Original Operating Instructions 150000747_02_en
349
BP000-245
Press a bale (2) until ¾ of its length have exited the bale channel (1).
Æ
The signal sheet (3) does not cover the sensor (4).
Æ
The sensor (4) is unattenuated (there is no iron in front of the sensor).
ü
The machine is shut down and safeguarded,
.
Check dimension X, measured between the upper edge of the sensor (4) and the edge of
the signal sheet (3).
Æ
If the dimension is
X=5 mm
, the setting is correct.
Æ
If the dimension
is not X=5 mm
, the sensor must be set.
Setting
Loosen the nuts (5) on both sides of the sensor (4).
Push the sensor (4) upwards until dimension is
X=5 mm
between the upper edge of the
sensor (4) and the edge of the signal sheet (3).
Tighten the nuts (5) (tightening torque = 10 Nm).
During the sensor test, check that the sensor (4) is still unattenuated,
.
Æ
The sensor has been set correctly if the sensor test shows that the sensor is unattenuated.
Æ
If the sensor test shows that the sensor is attenuated, adjust the sensor until the sensor test
shows that the sensor is unattenuated.
BP000-246