21
Malfunction, cause and remedy
21.1
Malfunctions electrics/electronics
254
BiG Pack 1270
Original Operating Instructions 150000747_02_en
522022-
L>MAX
Baling force on the left
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
The baling force on the left
baling flap has been ex-
ceeded.
In manual mode:
Reduce the target baling flap pressure.
In automatic mode:
If the alarm occurs frequently, reduce the target baling
force.
522023-
R>MAX
Baling force on the right
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
The baling force on the right
baling flap has been ex-
ceeded.
In manual mode:
Reduce the target baling flap pressure.
In automatic mode:
If the alarm occurs frequently, reduce the target baling
force.
522024-
Lower twine
Possible cause:
Remedy
FMI 7: The mechanism does not respond or an expected event does not occur.
The lower twine is torn.
Check the twine and the twine tensioner.
522025-
1
Upper twine 1
Possible cause
Remedy
FMI 1: The lower limit value was far below the required one.
On the upper twine, the min-
imum twine length has not
been reached when trying to
tie a knot.
Check the knotter and the knotter triggering.
Have the sensor adjusted.
522026-
2
Upper twine 2
Possible cause
Remedy
FMI 1: The lower limit value was far below the required one.
On the upper twine, the min-
imum twine length has not
been reached when trying to
tie a knot.
Check the knotter and the knotter triggering.
Have the sensor adjusted.